Bussmann FRS-R-40ID Fusetron® Time-Delay Fuse; Class RK5, 40 Amp, 600 Volt AC, 250 Volt DC, Holder Mount, Clip

  • Cooper Bussmann FRS-R-40ID Bussmann FRS-R-40ID Fusetron® Time-Delay Fuse; Class RK5, 40 Amp, 600 Volt AC, 250 Volt DC, Holder Mount, Clip
  • Bussmann FRS-R-40ID Fusetron® Time-Delay Fuse; Class RK5, 40 Amp, 600 Volt AC, 250 Volt DC, Holder Mount, Clip
Manufacturer: Cooper Bussmann
Mfr. #: FRS-R-40ID
Item #: 144125
UPC: 051712204620
Login for Availability
Your Price:

Product Details

Size: 1.060 Inch Diameter x 5.500 Inch Length

Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high-performance, short-circuit and overload protection

The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of 10 sec

Detailed Description: Bussmann Fusetron® Dual element time-delay fuse is designed to provide a higher degree of short-circuit protection in circuits that surge currents or temporary overloads occur. It measures 1.060 Inch diameter x 5.500 Inch. It is rated at a current of 40 Amps and a voltage of 600 VAC. It features insulated end caps that reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing. It helps in providing maximum over current protection and it simplifies/improves blackout prevention. It has a ferrule type terminal that insures reliable electrical connections when terminating stranded flexible wire in terminal blocks or other control devices. It features 2:1 selective coordination ratio that prevents electrical shutdowns from extending beyond the failed circuit.

Dual-element fuse can be applied in circuits subject to temporary motor overloads and surge currents for providing both high-performance, short-circuit and overload protection. Time delay fuse makes it possible to use fuse ampere ratings that are much smaller than those of non-time-delay fuses. It has an interrupt rating of 200000 Amps RMS symmetrical and a diameter of 0.81 Inch. It helps in protecting motors against burnout from overloads. Fuse gives motor running back-up protection to motors and is highly efficient. It can be used in the applications like power panel boards and motor control centers. Time-delay fuse is UL listed and CSA certified.

Product Specification

Amperage Rating 40 A
Application Ind Facilities & Factories - Facility: Safety and Security Systems
Brand Eaton
Catalog Description 40AMP 600V RK5 TD CURRENT LMTG FUSE
Connection Ferrule end x ferrule end
Element Dual
GTIN

00051712204620

Height 0.9000
Height Unit IN
Interrupt Rating 20 kAIC at 250 Vdc200 kAIC at 600 Vac
Item Status A
Length 1.0000
Length UOM IN
Mfr. # FRS-R-40ID
Response Time 10 S at 500%
Size 1.06 In Diameter X 5.50 In Length
Standard CE Marked
Type Fuse
UNSPSC 39121606
Voltage Rating 600 Vac, 250 Vdc
Width 5.4000