Eaton / Cutler Hammer 3BR3042B125 Main Circuit Breaker Load Center; 208Y/120/240 Volt, 125 Amp, 42 Circuits, 4-Wire, 3-Phase

  • Eaton / Cutler Hammer 3BR3042B125 Eaton / Cutler Hammer 3BR3042B125 Main Circuit Breaker Load Center; 208Y/120/240 Volt, 125 Amp, 42 Circuits, 4-Wire, 3-Phase
  • Eaton / Cutler Hammer 3BR3042B125 Main Circuit Breaker Load Center; 208Y/120/240 Volt, 125 Amp, 42 Circuits, 4-Wire, 3-Phase
Manufacturer: Eaton / Cutler Hammer
Mfr. #: 3BR3042B125
Item #: 223339
UPC: 786676440257
Login for Availability
Your Price:

Product Details

Size: 14.31 Inch Width x 27 Inch Height x 3.88 Inch Depth

All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with a neutral bonding strap pre-attached (commercial loadcenters do not have a pre-attached bonding strip)

The maximum main rating of the panel is the main circuit breaker rating when used as service entrance equipment

Type ld circuit breaker is not series rated with types br, bd and bj branch circuit breakers

22 KAIC series combination rating is obtained when types BD, BR, BQ, BQC and GFCB branch breakers are used with brh main

Loadcenter with combination cover only

100 kaic series combination rating is obtained when types bd, br, bq, bqc and gfcb branch breakers are used with chh main

Detailed Description: Eaton / Cutler Hammer 3-Phase Main circuit breaker load center has a current rating of 125 Amps and an interrupt rating of 10 kilo-Amps. Load center can easily accommodate copper/aluminum wires size of 1 - 2/0 coil at 60%/75% XDDC. It measures 14.31 Inch x 27 Inch x 3.88 Inch. Reliable breaker has NEMA 1 rated metallic enclosures for added safety. The 42-Pole load center has a voltage rating of 208Y/120Volts or 240 Volts for reliable performance. It features tin plated aluminum bus for enhanced conductivity and corrosion resistance. The 4-wire load center comes with 30 spaces and has no feed-thru lugs. It provides door lock and key included with load center for feasible operation. It is ideal to use in strip malls, small office buildings, high rise residential buildings and areas where reduced depth is required. Main circuit breaker load center is UL listed.

Product Specification

Amperage Rating 125 A
Application Elec Assemblies, Panels & EOEM - Electrical Assemblies, Panels and EOEMsOtherGeneration - Renewable Energy - Alternative EnergyGeneration - Conventional Energy - Conventional EnergyDatacenters - IT Space: CI and Hyper ConvergedMarine Vessels and Equipment - Marine Vessels and Equipment - Other
Brand Eaton
Catalog Description Eaton BR main breaker loadcenter,No feed-thru lugs,Main circuit breaker,125 A,L1,Aluminum,Cover included,NEMA 1,Metallic,10 kAIC,CC,42 Circuits,30 Spaces,Four-wire,Three-phase,#6-4/0 AWG Cu/Al,Combination,NEMA 1,208 Y/120, 240 V
Cover Type Cover included
GTIN

00786676440257

Height 4.5000
Height Unit IN
Interrupt Rating 10 kAIC
Item Status A
Length 40.5000
Length UOM IN
Mfr. # 3BR3042B125
Mounting Combination
Number of Spaces 30
Phase Three-phase
Size L1
Special Features No feed-thru lugs
Standard UL 67,UL 50
Type Main breaker loadcenter
UNSPSC 39121101
Voltage Rating 208Y/120, 240V
Width 15.5000
Width UOM IN