Sign in or register to view your pricing and inventory.

Eaton / Cutler Hammer FAZ-D16/2-NA EMD Branch Circuit Breaker; 16 Amp, 2-Pole, DIN-Rail Mount

  • Eaton / Cutler Hammer FAZ-D16/2-NA Eaton / Cutler Hammer FAZ-D16/2-NA EMD Branch Circuit Breaker; 16 Amp, 2-Pole, DIN-Rail Mount
  • Eaton / Cutler Hammer FAZ-D16/2-NA EMD Branch Circuit Breaker; 16 Amp, 2-Pole, DIN-Rail Mount
Manufacturer: Eaton / Cutler Hammer
Mfr. #: FAZ-D16/2-NA
Item #: 150325
UPC: 015081020663
Login for Availability
Your Price:

Product Details

Dimension: 35.3 mm Width x 105 mm Height

Trip-free design-breaker can not be defeated by holding the handle in the ON position

Captive screws cannot be lost

SWD (switching duty)- suitable for switching fluorescent lighting loads (in <= 20 Amp)

Field installable shunt trip and auxiliary switch subsequent mounting

Contact Position Indicator (red/green)

Possibility for sealing the toggle in ON or OFF position

Quick fastening with two lock-in positions on IEC/EN 60715

Detailed Description: Eaton / Cutler Hammer FAZ series type D 3-Pole miniature circuit breaker is designed specially for high inductive loads where high levels of inrush current are expected. It is ideal for convenience receptacle circuits, motor control circuits, computers, relays, UPS, HACR equipment and other branch service applications. It features thermal magnetic trip mechanism that operates to provide over current protection. Captive terminal screws come with finger and back-of-hand protection.

Circuit breaker has a current rating of 3 Amps and voltage rating of 480 VAC and 48 VDC. It measures 35.3 mm x 105 mm. It features instantaneous trip current of 10 - 20X that causes the circuit breaker to trip without intentional time delay. It is toggle operated for hands free mechanism for added safety. It has an interrupting capacity of 10, 15 kilo-Amps that reduces the let-through current and energy, which can damage the circuit. It has AIR rating of 10 kilo-Amps for extreme tropical conditions. Circuit breaker is UL listed, CSA certified.

Product Specification

Dimensions 35.3 mm Width x 105 mm Height
Amperage Rating 16 Amp
Application For Convenience Receptacle Circuits (Internal/External), Motor Control Circuits, Load Circuits Leaving the Equipment (External), Hacr Equipment (Heating, Air Conditioning, Refrigeration), (Internal/External), Plc I/O Points, Computers, Power Supplies, Control Instrumentation, Relays, UPS, Power Conditioners
Brand Eaton / Cutler Hammer
Connection Screw Terminal
Environmental Conditions >= 20,000 Operations Endurance
Frame 45
Interrupt Rating 10 Kilo-Amp (UL/CSA), 15 Kilo-Amp (IEC)
Item Branch Circuit Breaker
Mfr. # FAZ-D16/2-NA
Mounting DIN-Rail
Number Of Poles 2
Standards UL 489 Listed File #E235139, CSA Certified C22.2 No.5-02, VDE/ABS/RoHS Compliant
Trip Range 10 - 20 x In
Trip Type D-Curve, Thermal-Magnetic
Type EMD
Voltage Rating 480 Volt AC, 48 Volt DC
Wire Size (1) 18-6 AWG, (2) 18-10 AWG