Size: 4.250 Inch Length x 3.250 Inch Width x 7.500 Inch Height
Leviton's outstanding surge protection devices divert damaging voltage transients, or surges, away from electronic equipment
Transients are diverted away from sensitive micro circuitry, providing protection against catastrophic failure, costly downtime and data disruptions
Real time protection status LEDs and audible alarm diagnostics
Dry contact leads-N.O./N.C. form C rated at 7Amps at 240 Volt AC or 30 Volt DC remote monitoring
Detailed Description:
Leviton 3-Phase Surge protection device features NEMA 3R powder coated steel outer enclosure that offers more durability. It is ideal for commercial application. Surge protection device can be panel mounted for easy connection. It has a voltage rating of 120/240 Volts in hi-leg delta configuration. Surge protection device comes with 40 mm MOV design surge technology. It has recommended circuit breaker rating of 30 Amps. It has flammability rating of V-2 per UL94. It has a frequency rating of 50/60 Hz. Surge protection device operates at a temperature of -10 C to 60 C. It measures 4.250 Inch x 3.250 Inch x 7.500 Inch.
Surge protection device has relative humidity of 5% to 95% non-condensing. It accommodates parallel hardwire connection through 12 AWG wire that offers good conductivity. Surge protection device features real-time diagnoses and provide the status of LEDs, audible alarm. It has dry contact remote monitoring NO/NC leads that are form C rated at 7 Amps with 240 VAC/30 VDC. Surge protection device includes maximum continuous operating voltage of line to neutral is 150 Volts, line to ground is 300 Volts, neutral to ground is 150 Volts and line to line is 254 Volts.
Surge protection device includes storage temperature of -20 deg C to 85 deg C. It has voltage protection rating of line to neutral is 800 Volts, line to ground is 1200 Volts, neutral to ground is 700 Volts and line to line is 1000 Volts. Surge protection device includes nominal discharge current rating of 3 kilo-Amps. It has maximum surge current of 80 kilo-Amps per mode. Surge protection device includes short circuit current rating of 100 kilo-Amps. It has noise rejection of -30 dB at 40 db at 10 kHz-10 MHz. Surge protection device is CULUS listed and meets ANSI/NEMA standards.
Application | Commercial |
Brand | Leviton |
Catalog Description | 120/240/120 Volt Hi-Leg Split Phase Delta Panel Protector, Enhanced Noise Filtering, NEMA 3R Enclosure |
Connection | Parallel Hardwired via 12AWG wire |
Depth | 3.25 |
Environmental Conditions | Flammability (Rated UL 94 V-2);Humidity (5 to 95% Non-Condensing);Storage temperature (-20 to +85 DEGC) |
GTIN |
00078477864883 |
Height | 7.50 |
Item Status | A |
Material | Powder Coated Steel |
Mfr. # | 42412-DS3 |
Phase | 3 |
Short Circuit Rating | 100 |
Standard | ANSI\IEEE (Category C-62.41, C-62.45);cULus Listed (1449);NEMA |
Type | Type 2 SPD |
Type Of Indicators | Noise Filtering |
UNSPSC | 39121610 |
Width | 4.25 |