Sign in or register to view your pricing and inventory.

Littelfuse SLC010 Powr-Gard® Class G Time-Delay Fuse; 10 Amp, 600 Volt AC/170 Volt DC

  • Littelfuse SLC010 Littelfuse SLC010 Powr-Gard® Class G Time-Delay Fuse; 10 Amp, 600 Volt AC/170 Volt DC
  • Littelfuse SLC010 Powr-Gard® Class G Time-Delay Fuse; 10 Amp, 600 Volt AC/170 Volt DC
Manufacturer: Littelfuse
Mfr. #: SLC010
Item #: 201810
UPC: 079458420654
Login for Availability
Your Price:

Product Details

Size: 0.405 Inch x 1.311 Inch

Detailed Description: Littelfuse Powr-Gard® SLC Series Class G Current-limiting fuse is rated at 10 Amps/600 VAC/170 VDC and has an interrupt rating of 100 kilo-Amps VAC/10 kilo-Amps VDC. It measures 0.405 Inch x 1.311 Inch. Fuse features current limiting design to reduce damage to equipment due to heating and magnetic effects of short circuit currents. It offers medium time-delay that reduces downtime caused by power surges or equipment demands. Current-limiting fuse has varying length to avoid over-fusing and provides economic branch circuit protection. It can be use with LG300 series and L30030G series fuse holders. Fuse is UL listed and CSA certified.

Product Specification

Application Branch Circuit
Brand Littelfuse
Catalog Description UL CLASS G MEDIUM TIME DELAY 10A. The unique design of LittelfuseÆs compact SLC series Class G fuses provide additional time-delay over competitive products which increases system reliability. Compact Class G fuses were the first fuse series to approach midget fuse dimensions and meet NEC requirements for branch-circuit protection. The unique dimensions of SLC series Class G fuses prevents insertion of lower voltage fuses in Class G fuse holders. The fuseÆs varying length prevents insertion of higher ampere rated fuses in fuse holders designed for lower ampere ratings. Class CC fuses are replacing Class G fuses in many new designs. Class CC fusesÆ superior time delay plus higher voltage and interrupting ratings meet the needs of modern circuits. LittelfuseÆs introduction of POWR-PRO« CCMR series fuses, with ratings up to 60 Amperes for providing branch circuit protection, are accelerating this trend. Safety: 100,000 A.I.R. ù Reliable interruption of all overcurrents up to 100,000 amperes. Current limiting design reduces damage to equipment caused by heating and magnetic effects of short circuit currents. Medium time-delay allows fuses to be sized closer to actual equipment requirements ù no need to greatly oversize to withstand harmless equipment or system surges. Reduced Downtime: Medium time-delay may reduce downtime caused by power surges or equipment demands.
GTIN

00079458420654

Height 1.0000
Height Unit IN
Item Status A
Length 2.2500
Length UOM IN
Mfr. # SLC010
Special Features Time-Delay
Standard Standard 248-5 UL Listed/CSA
Type Class G
UNSPSC 39121627
Width 1.5000
Width UOM IN