Torque and speed accuracy at very low speed, high dynamic performance with Flux Vector Control
Extended frequency range for high-speed motors
Parallel connection of motors and special drives using the voltage/frequency ratio
Static speed accuracy and energy saving for open-loop synchronous motors
Smooth flexibility for unbalanced machines with the ENA System
Detailed Description: Square D by Schneider Electric Altivar 71 drive integrates the Modbus and CAN open protocols as standard, as well as numerous functions. These functions can be extended using communication option cards I/O extension cards, an encoder interface or a Controller Inside programmable card. This range can be used for controlling asynchronous motors in sensor/sensorless flux vector control mode. At 200?240 V a and 380?480 V a, there is a special version available that can be used for controlling synchronous motors with sinusoidal electromotive force when there is speed feedback.
Application | 11 KW, 3 PHASE 380...480 V,15 HP, 3 PHASE 380...480 V,ASYNCHRONOUS MOTORS-SYNCHRONOUS MOTORS,COMPLEX, HIGH-POWER MACHINES |
Brand | ALTIVAR 71 |
Catalog Description | Schneider Electric,SPEEDDRIVE,15HP,460V,ATV71LED KEYPAD,11kW,3 phases,3-Phase,3-Phase,400/480VAC,Altivar 71,Altivar 71,IP20,Modbus-CANopen,Modbus-CANopen,complex, high-power machines,variable speed drive |
Control | +/- 0.01 OF NOMINAL SPEED IN CLOSED-LOOP MODE WITH ENCODER FEEDBACK 0.2 TN TO TN-+/- 10 OF NOMINAL SLIP WITHOUT SPEED FEEDBACK 0.2 TN TO TN |
Display | DRIVE VOLTAGE 1 LED RED) |
Enclosure | IP20 |
Environmental Conditions | -10-50 AC WITHOUT) |
GTIN |
00785901449553 |
Item Status | A |
Mfr. # | ATV71HD11N4Z |
Size | 210 MM,213 MM,295 MM |
Special Features | ENA (ENERGY ADAPTATION) SYSTEM FOR UNBALANCED LOADS-SENSORLESS FLUX VECTOR CONTROL (SFVC) (VOLTAGE OR CURRENT VECTOR)-VOLTAGE/FREQUENCY RATIO (2 OR 5 POINTS)-FLUX VECTOR CONTROL (FVC) WITH SENSOR (CURRENT VECTOR),ADJUSTABLE PI REGULATOR,AGAINST EXCEEDING LIMIT SPEED DRIVE-SHORT-CIRCUIT BETWEEN MOTOR PHASES DRIVE-THERMAL PROTECTION DRIVE-MOTOR PHASE BREAK MOTOR-POWER REMOVAL MOTOR-THERMAL PROTECTION MOTOR-AGAINST INPUT PHASE LOSS DRIVE-BREAK ON THE CONTROL CIRCUIT DRIVE-INPUT PHASE BREAKS DRIVE-LINE SUPPLY OVERVOLTAGE DRIVE-LINE SUPPLY UNDERVOLTAGE DRIVE-OVERCURRENT BETWEEN OUTPUT PHASES AND EARTH DRIVE-OVERHEATING PROTECTION DRIVE-OVERVOLTAGES ON THE DC BUS DRIVE,INTERNAL SUPPLY FOR REFERENCE POTENTIOMETER (1 TO 10 KOHM) 10.5 V DC +/- 5 , <10 MA OVERLOAD AND SHORT-CIRCUIT PROTECTION-INTERNAL SUPPLY 24 V DC 21-27 V), <200 MA OVERLOAD AND SHORT-CIRCUIT PROTECTION,TERMINAL 2.5 MMA, AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)-TERMINAL 16 MMA, AWG 4 L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) |
Standard | 1 GN 13-200 HZ)EN/IEC 60068-2-6-1.5 MM PEAK TO PEAK 3-13 HZ)EN/IEC 60068-2-6,1.2/50 AS - 8/20 AS SURGE IMMUNITY TEST LEVEL 3 IEC 61000-4-5-CONDUCTED RADIO-FREQUENCY IMMUNITY TEST LEVEL 3 IEC 61000-4-6-ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST LEVEL 4 IEC 61000-4-4-ELECTROSTATIC DISCHARGE IMMUNITY TEST LEVEL 3 IEC 61000-4-2-RADIATED RADIO-FREQUENCY ELECTROMAGNETIC FIELD IMMUNITY TEST LEVEL 3 IEC 61000-4-3-VOLTAGE DIPS AND INTERRUPTIONS IMMUNITY TEST IEC 61000-4-11,15 GN 11 MS EN/IEC 60068-2-27,CE,EN 61800-3 ENVIRONMENTS 2 CATEGORY C3-EN 55011 CLASS A GROUP 2-IEC 60721-3-3 CLASS 3S2-EN/IEC 61800-5-1-EN 61800-3 ENVIRONMENTS 1 CATEGORY C3-UL TYPE 1-EN/IEC 61800-3-IEC 60721-3-3 CLASS 3C1,IP20 ON UPPER PART WITHOUT BLANKING PLATE ON COVER EN/IEC 60529-IP20 ON UPPER PART WITHOUT BLANKING PLATE ON COVER EN/IEC 61800-5-1-IP21 EN/IEC 60529-IP21 EN/IEC 61800-5-1-IP41 ON UPPER PART EN/IEC 60529-IP41 ON UPPER PART EN/IEC 61800-5-1-IP54 ON LOWER PART EN/IEC 60529-IP54 ON LOWER PART EN/IEC 61800-5-1,UL-C-TICK-GOST-CSA-NOM 117 |
Sub-Brand | ALTIVAR 71 |
Type | VARIABLE SPEED DRIVE |
UNSPSC | 39122001 |