Dimension: 2.125 Inch Length x 1.375 Inch Width
All connections must be made in an enclosure for proper installations
Built-in auto reset, soft start, short and overload circuit protection features
The soft start delayed start feature extends lamp life by delaying the abrupt inrush current to the lamp
In the case of a system overload or short circuit the transformer will revert to a hold position and then automatically reset the system when the problem is solved
System protection is designed to last several hours
Used as a replacement part for factory installed transformers
Detailed Description: WAC Lighting Non-enclosed electronic transformer in black color is designed to replacement part for factory installed transformers or installed in a properly listed enclosure. It measures 2.125 Inch x 1.375 Inch. It has voltage rating of 12 and power rating of 75 Watts. It features built in auto reset, soft start, short and overload circuit protection. The soft start delayed start feature extends lamp life by delaying the abrupt inrush current to the lamp. All connections must be made in an enclosure for proper installations. Non-enclosed electronic transformer is UL listed.
Application | Used As A Replacement Part For Factory Installed Transformers |
Brand | WAC Lighting |
Catalog Description | Wac Lighting EN-1275-R-AR Electronic Transformer, Low Voltage, Non-Enclosed, EN-1275-R-AR, 120 V Input, 12 V Output, 20 - 75 WTT, 20 KHZ, Black, 2-1/2 IN Length, 1-3/8 IN Width, 1 IN Height, Polycarbonate, Aluminum, 0.625 AMP At 120 V Maximum Input Amperage, UL E204239, 2108 Listed, Used As A Replacement Part For Factory Installed Transformers |
Country Of Origin | US |
Finish 2 | Black |
Frequency Rating | 20 Kilo Hz |
GTIN |
00790576094618 |
Height | 1 Inch |
Input Voltage | 120 Volt |
Item | Electronic Transformer |
Length | 2-1/8 Inch |
Mfr. # | EN-1275-R-AR |
Model | EN-1275-R-AR |
Output Voltage | 12 Volt |
Power Rating | 75 Watt |
Special Features | Transformer may be safely loaded to 100 PCT of stated capacity ; Built-in auto reset, soft start, short and overload circuit protection features ; Soft start delayed start feature extends lamp life ; Dimmable with electronic low voltage dimmers, dimmers should always be installed on the primary side of the transformer ; In the case of a system overload or short circuit the transformer will revert to a ôholdö position and then automatically reset the system when the problem is solved ; System protection is designed to last several hours ; True RMS meter is required to read the high frequency output ; Accessories: METB û Enclosure and connection box, MTB-01 û Terminal block ; All connections must be made in an enclosure for proper installations ; 5 YR product warranty |
Standard | UL E204239, 2108 Listed |
Standards | UL E204239, 2108 Listed |
Type | Non-Enclosed |
Wattage | 20 - 75 |
Width | 1-3/8 Inch |